TEKBOX and RIGOL - EMI Specific Solutions and Highlights

The Rigol DSA series of spectrum analyzers are ideal for performing near-field probing, conducted, and emitted precompliance measurements.
They Feature:
- Operating frequency ranges up to 7.5GHz
- Low DANL (from -135 to -161dBm based on model)
- On-sceen limit lines (standard)
- Preamplifiers (standard on DSA815 and DSA1030A models, optional on all others)
- Quasi-Peak detectors/FCC RBWs of 200Hz, 9kHz, and 120kHz, and -6dB EMI filter (standard on DSA1030, option DSA800-EMI on others)

Neue Aktion: EMI Bundle DSA815-TG zusammen mit EMI Bundle (S1210 EMI PreCompliance Software, EMI-DSA800 license option for a spectrum analyzer und NFP-3 set of Near Field Probes)
Zum Vorteilspreis mit 22% Rabatt auf den Listenpreis! Wir bieten Ihnen gerne auch andere Kombinationen an bis DSA875-TG.
DSA815-TG EMI Bundle Komplett mit Analyzer DSA815-TG plus EMI Bundle DSA800-EMI Option , die NFP-3 NearField Probes und die S1012 EMI Pre-Compliance Software für den PC. Bundle Vorteil 22% auf den Listenpreis Gilt solange Vorrat. CHF 2'715.00 >> DSA815-TG EMI Bundle

Neu - DSA800 EMI Pre-Compliance Bundle (nur zusammen mit einem neuen RIGOL DSA800 Serie Analyzer)
- The EMI Bundle includes the S1210 EMI PreCompliance Software, the EMI-DSA800 license option for a spectrum analyzer, and a NFP-3 set of Near Field Probes all at a substantial discount. This offer is only available with a new Spectrum Analyzer
Mehr >>> DSA EMI Bundle

EMC Precompliance: Testing on a budget - Part 1
Solution: Almost any electronic design slated for commercial use is subject to
EMC (Electromagnetic Compatibility) testing. Any company intending to sell
these products into a country must ensure that the product is tested versus
specifications set forth by the regulatory body of that country. In the US, the
FCC specifies rules on EMC testing. CISPR and IEC are also used throughout the
world.

EMC Precompliance: Testing on a budget - Part 2
To be sold legally, a sample of the electronic product must pass a series of
tests performed by accredited compliance companies. This full compliance testing
can be very expensive with many labs charging thousands of dollars for a single
day of testing. Testing a product for full compliance can also require specialized
testing environments and no changes can be made during the testing. Any failures
in compliance testing require that the design heads back to Engineering for
analysis and possible redesign. This can cause delays in product release and an
obvious increase in design costs.
One method to lower the additional costs associated with EMC compliance
is to perform EMC testing throughout the design process well before sending the
product off for full compliance testing. This pre-compliance testing can be very
cost effective and can be tailored to closely match the conditions used for
compliance testing. This will increase your confidence in passing compliance the
first time through, lower your test costs, and speed your time to market.

EMC pre-compliance testing -- emc-pre-compliance-testing.pdf [524 KB]

RIGOL App Note -- app_note_dsa815-precompliance [391 KB]

EMI Measurement with Near Field Probes
With additional options like the EMI Filter & Quasi Peak Detector and the Advanced
Measurement Kit the spectrum analyzer DSA815-TG is ideal for pre compliance tests of boards, devices and components. This allows customers to troubleshoot and test designs on
their bench without having to schedule and pay for time at a full compliance lab. The pre
testing helps engineers to stay within the EU-wide regulations for EMC already during the
design phase and prevents from very expensive re-designs. It results in reduced development
time and accelerated time-to-market.
Although the DSA815-TG does not perform exactly like a fully compliant EMC test
instrument according to CISPR 16-1-1, it is ideal for all necessary pre-tests

Übersicht lieferb. Geräte - Lösungen auf Anfrage

TEKBOX LISN 50uH TEKBOX EMV Zubehör - EMV Precompliance - LISN TBLC08 50uH Line Impedance Stabilisation Network LISN - CISPR 16 985.00 CHF

TEKBOX LISN 5uH 5uH Line Impedance Stabilisation Network LISN - CISPR 25The TBOH01 5ÁH LISN is a device required to setup conducted noise measurements of DC-powered devices. It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz 375.00 CHF

TEKBOX EMC Near Field Probes / 40dB Amp The H20, H10, H5 and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre-compliance measurements. The probes are used in the near field of sources of electromagnetic radiation. 585.00 CHF

TEKBOX EMC Near Field Probes / 20dB Amp The H20, H10, H5 and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre-compliance measurements. The probes are used in the near field of sources of electromagnetic radiation. 495.00 CHF

TEKBOX Active Load TEKBOX EMV Zubehör - Active Load TBOH02 Self Powered Active Load Overview The TBOH02 is a self powered, precision active load. It does not need a separate supply voltage and operates as low as 2V... 245.00 CHF

TEKBOX Mod Wideband Driver Amplifier TBMDA1 Modulated Wideband Driver Amplifier 450.00 CHF

TEKBOX TEM Cell 1 A TEM cell is a stripline device for radiated emissions and immunity testing of electronic devices. It is not a replacement, but due to its size and cost it is a convenient alternative to measurements in an anechoic chamber. 895.00 CHF

TEKBOX TEM Cell 2 A TEM cell is a stripline device for radiated emissions and immunity testing of electronic devices. It is not a replacement, but due to its size and cost it is a convenient alternative to measurements in an anechoic chamber. 1'195.00 CHF

TEKBOX TEM Cell 3 A TEM cell is a stripline device for radiated emissions and immunity testing of electronic devices. It is not a replacement, but due to its size and cost it is a convenient alternative to measurements in an anechoic chamber. 1'495.00 CHF